Marstech Unlimited Solutions and Technology Inc.

Our Products

  • New Products

  • Outdoor Fiber Optic Cables

  • Indoor Fiber Optic Cables

  • Active Equipments

    • Media Converter

  • Fiber Management System

    • Optical Distribution Frame

    • Closure

  • Cable Assemblies

  • Test Instruments

  • Fusion Splicing Machine & Tools

  • Adapters & Attenuators

  • FTTH Accessories

  • CATV Equipments

  • Digital Equipments

  • OPGW & ADSS Accessories

  • Structured Cabling Accessories

    • Structured Cabling

    • DDF

  • Jumper, Messenger Wire & Coax Cable

Search
<p><span style="font-size: small;"><strong style="font-size: small;">Specification:</strong><br /></span></p>
<table class="data" style="width: 100%;" cellspacing="0" cellpadding="0">
<tbody>
<tr>
<td><strong><em><span style="font-size: small;">Fiber Capacity<br /></span></em></strong></td>
<td><span style="font-size: small;">12</span></td>
</tr>
<tr>
<td><strong><em><span style="font-size: small;">No. of Splice Tray</span></em></strong></td>
<td><span style="font-size: small;">1</span></td>
</tr>
<tr>
<td><strong><em><span style="font-size: small;">Fiber Capacity per Splice Tray </span></em></strong></td>
<td><span style="font-size: small;">12</span></td>
</tr>
<tr>
<td><strong><em><span style="font-size: small;">Splicing Methods</span></em></strong></td>
<td><span style="font-size: small;">Fusion &amp; Mechanical Methods<br /></span></td>
</tr>
<tr>
<td><strong><em><span style="font-size: small;">Cable Diameter</span></em></strong></td>
<td><span style="font-size: small;">8 ~ 32 mm<br /></span></td>
</tr>
<tr>
<td><strong><em><span style="font-size: small;">Cable Capacity</span></em></strong></td>
<td><span style="font-size: small;">1</span></td>
</tr>
<tr>
<td><strong><em><span style="font-size: small;">Connector Type</span></em></strong></td>
<td><span style="font-size: small;">SC / FC</span></td>
</tr>
<tr>
<td><strong><em><span style="font-size: small;">Material</span></em></strong></td>
<td><span style="font-size: small;">Aluminum, SPCC</span></td>
</tr>
<tr>
<td><strong><em><span style="font-size: small;">Type</span></em></strong></td>
<td><span style="font-size: small;">Drawer | Swing-out<br /></span></td>
</tr>
<tr>
<td><strong><em><span style="font-size: small;">Installation</span></em></strong></td>
<td><span style="font-size: small;">19" Open Rack/ Cabinet</span></td>
</tr>
</tbody>
</table>

12 Core Fiber Distribution Frame
<p><span style="font-size: small;"><strong style="font-size: small;">Specification:</strong><br /></span></p>
<table class="data" style="width: 100%;" cellspacing="0" cellpadding="0">
<tbody>
<tr>
<td><span style="font-size: small;"><strong><em>Size (mm) (LxWxH)</em></strong></span></td>
<td><span style="font-size: small;">483 x 310 x 222</span></td>
</tr>
<tr>
<td><span style="font-size: small;"><strong><em>Fiber Capacity<br /></em></strong></span></td>
<td><span style="font-size: small;">48</span></td>
</tr>
<tr>
<td><span style="font-size: small;"><strong><em>No. of Splice Tray</em></strong></span></td>
<td><span style="font-size: small;">2</span></td>
</tr>
<tr>
<td><span style="font-size: small;"><strong><em>Fiber Capacity per Splice Tray </em></strong></span></td>
<td><span style="font-size: small;">24</span></td>
</tr>
<tr>
<td><span style="font-size: small;"><strong><em>Splicing Methods</em></strong></span></td>
<td><span style="font-size: small;">Fusion &amp; Mechanical </span></td>
</tr>
<tr>
<td><span style="font-size: small;"><strong><em>Connector Type</em></strong></span></td>
<td><span style="font-size: small;">SC / FC </span></td>
</tr>
<tr>
<td><span style="font-size: small;"><strong><em>Cable Diameter</em></strong></span></td>
<td><span style="font-size: small;">8~32 mm</span></td>
</tr>
<tr>
<td><span style="font-size: small;"><strong><em>Cable Capacity</em></strong></span></td>
<td><span style="font-size: small;">4</span></td>
</tr>
<tr>
<td><span style="font-size: small;"><strong><em>Installation</em></strong></span></td>
<td><span style="font-size: small;">19" Open Rack/ Cabinet </span></td>
</tr>
</tbody>
</table>

48 Fiber Distribution Frame
<p><span style="font-size: small;"><strong style="font-size: small;">Specification:</strong><br /></span></p>
<table class="data" style="width: 100%;" cellspacing="0" cellpadding="0">
<tbody>
<tr>
<td><span style="font-size: small;"><strong><em>Size (mm) (LxWxH)</em></strong></span></td>
<td><span style="font-size: small;">483 x 310 x 133</span></td>
</tr>
<tr>
<td><span style="font-size: small;"><strong><em>Fiber Capacity<br /></em></strong></span></td>
<td><span style="font-size: small;">24</span></td>
</tr>
<tr>
<td><span style="font-size: small;"><strong><em>No. of Splice Tray</em></strong></span></td>
<td><span style="font-size: small;">1</span></td>
</tr>
<tr>
<td><span style="font-size: small;"><strong><em>Fiber Capacity per Splice Tray </em></strong></span></td>
<td><span style="font-size: small;">24</span></td>
</tr>
<tr>
<td><span style="font-size: small;"><strong><em>Splicing Methods</em></strong></span></td>
<td><span style="font-size: small;">Fusion &amp; Mechanical<br /></span></td>
</tr>
<tr>
<td><span style="font-size: small;"><strong><em>Connector Type<br /></em></strong></span></td>
<td><span style="font-size: small;">SC / FC</span></td>
</tr>
<tr>
<td><span style="font-size: small;"><strong><em>Cable Diameter</em></strong></span></td>
<td><span style="font-size: small;">8 ~ 32 mm<br /></span></td>
</tr>
<tr>
<td><span style="font-size: small;"><strong><em>Cable Capacity</em></strong></span></td>
<td><span style="font-size: small;">4</span></td>
</tr>
<tr>
<td><span style="font-size: small;"><strong><em>Installation</em></strong></span></td>
<td><span style="font-size: small;">19" Open Rack/ Cabinet</span></td>
</tr>
</tbody>
</table>

24 Core Fiber Distribution Frame
<p><span style="font-size: small;"><strong style="font-size: small;">Specification:</strong><br /></span></p>
<table class="data" style="width: 100%;" cellspacing="0" cellpadding="0">
<tbody>
<tr>
<td><strong><em><span style="font-size: small;">Fiber Capacity<br /></span></em></strong></td>
<td><span style="font-size: small;">12</span></td>
</tr>
<tr>
<td><strong><em><span style="font-size: small;">No. of Splice Tray</span></em></strong></td>
<td><span style="font-size: small;">1</span></td>
</tr>
<tr>
<td><strong><em><span style="font-size: small;">Fiber Capacity per Splice Tray </span></em></strong></td>
<td><span style="font-size: small;">12</span></td>
</tr>
<tr>
<td><strong><em><span style="font-size: small;">Splicing Methods</span></em></strong></td>
<td><span style="font-size: small;">Fusion &amp; Mechanical Methods<br /></span></td>
</tr>
<tr>
<td><strong><em><span style="font-size: small;">Cable Diameter</span></em></strong></td>
<td><span style="font-size: small;">8 ~ 32 mm<br /></span></td>
</tr>
<tr>
<td><strong><em><span style="font-size: small;">Cable Capacity</span></em></strong></td>
<td><span style="font-size: small;">1</span></td>
</tr>
<tr>
<td><strong><em><span style="font-size: small;">Connector Type</span></em></strong></td>
<td><span style="font-size: small;">SC / FC</span></td>
</tr>
<tr>
<td><strong><em><span style="font-size: small;">Material</span></em></strong></td>
<td><span style="font-size: small;">Aluminum, SPCC</span></td>
</tr>
<tr>
<td><strong><em><span style="font-size: small;">Type</span></em></strong></td>
<td><span style="font-size: small;">Drawer | Swing-out<br /></span></td>
</tr>
<tr>
<td><strong><em><span style="font-size: small;">Installation</span></em></strong></td>
<td><span style="font-size: small;">19" Open Rack/ Cabinet</span></td>
</tr>
</tbody>
</table>

12 Core Fiber Distribution Frame (Drawer Type)
<p><span style="font-size: small;"><strong style="font-size: small;">Specification:</strong><br /></span></p>
<table class="data" style="width: 100%;" cellspacing="0" cellpadding="0">
<tbody>
<tr>
<td><span style="font-size: small;"><strong><em>Size (mm) (LxWxH)</em></strong></span></td>
<td><span style="font-size: small;">483 x 310 x 177</span></td>
</tr>
<tr>
<td><span style="font-size: small;"><strong><em>Fiber Capacity<br /></em></strong></span></td>
<td><span style="font-size: small;">72</span></td>
</tr>
<tr>
<td><span style="font-size: small;"><strong><em>No. of Splice Tray</em></strong></span></td>
<td><span style="font-size: small;">3</span></td>
</tr>
<tr>
<td><span style="font-size: small;"><strong><em>Fiber Capacity per Splice Tray </em></strong></span></td>
<td><span style="font-size: small;">24</span></td>
</tr>
<tr>
<td><span style="font-size: small;"><strong><em>Splicing Methods</em></strong></span></td>
<td><span style="font-size: small;">Fusion &amp; Mechanical<br /></span></td>
</tr>
<tr>
<td><span style="font-size: small;"><strong><em>Cable Types</em></strong></span></td>
<td><span style="font-size: small;">Loose Tube &amp; Ribbon<br /></span></td>
</tr>
<tr>
<td><span style="font-size: small;"><strong><em>Connector Type</em></strong></span></td>
<td><span style="font-size: small;">SC &amp; FC</span></td>
</tr>
<tr>
<td><span style="font-size: small;"><strong><em>Cable Diameter</em></strong></span></td>
<td><span style="font-size: small;">8 ~ 32 mm<br /></span></td>
</tr>
<tr>
<td><span style="font-size: small;"><strong><em>Cable Capacity</em></strong></span></td>
<td><span style="font-size: small;">4</span></td>
</tr>
<tr>
<td><span style="font-size: small;"><strong><em>Installation</em></strong></span></td>
<td><span style="font-size: small;">19" Open Rack/ Cabinet</span></td>
</tr>
</tbody>
</table>

72 Core Fiber Distribution Frame
<p><span style="font-size: small;"><strong style="font-size: small;">Specification:</strong><br /></span></p>
<table class="data" style="width: 100%;" cellspacing="0" cellpadding="0">
<tbody>
<tr>
<td><span style="font-size: small;"><strong><em>Size (mm) (LxWxH)</em></strong></span></td>
<td><span style="font-size: small;">483 x 310 x 222<br /></span></td>
</tr>
<tr>
<td><span style="font-size: small;"><strong><em>Fiber Capacity<br /></em></strong></span></td>
<td><span style="font-size: small;">144</span></td>
</tr>
<tr>
<td><span style="font-size: small;"><strong><em>No. of Splice Tray</em></strong></span></td>
<td><span style="font-size: small;">6</span></td>
</tr>
<tr>
<td><span style="font-size: small;"><strong><em>Fiber Capacity per Splice Tray </em></strong></span></td>
<td><span style="font-size: small;">24</span></td>
</tr>
<tr>
<td><span style="font-size: small;"><strong><em>Splicing Methods</em></strong></span></td>
<td><span style="font-size: small;">Fusion &amp; Mechanical<br /></span></td>
</tr>
<tr>
<td><span style="font-size: small;"><strong><em>Cable Types</em></strong></span></td>
<td><span style="font-size: small;">Loose Tube &amp; Ribbon<br /></span></td>
</tr>
<tr>
<td><span style="font-size: small;"><strong><em>Connector Type</em></strong></span></td>
<td><span style="font-size: small;">SC &amp; FC</span></td>
</tr>
<tr>
<td><span style="font-size: small;"><strong><em>Cable Diameter</em></strong></span></td>
<td><span style="font-size: small;">8 ~ 32 mm<br /></span></td>
</tr>
<tr>
<td><span style="font-size: small;"><strong><em>Cable Capacity</em></strong></span></td>
<td><span style="font-size: small;">4</span></td>
</tr>
<tr>
<td><span style="font-size: small;"><strong><em>Installation</em></strong></span></td>
<td><span style="font-size: small;">19" Open Rack/ Cabinet</span></td>
</tr>
</tbody>
</table>

144 Core Fiber Distribution Frame

Need a Quote?

click here or email us at
This email address is being protected from spambots. You need JavaScript enabled to view it.

09184055347



or call us now at

  • +63 ( 02 ) 8371-12-32
  • +63 ( 02 ) 8371-12-24
  • +63 ( 02 ) 8398-65-45
  • +63 ( 02 ) 8799-25-84
  •  +63 (02 ) 8332-17-42

Be Our Partner

As we are in the direction of offering a complete one-stop-shop convenience for our customers, Marstech is continuously looking for manufacturers/distributors of related products. If you are interested to be one of our partner-suppliers, please email us at: This email address is being protected from spambots. You need JavaScript enabled to view it.

 

CC BY-NC-SA 3.0 :: Valid XHTML | CSS